TGF fabric filters are used for cleaning the dusty exhaust air of hammer mills or air separators. The max. filter load is 100 m³ air per hour and m² filter surface.
Automatic cleaning for the filter elements can be supplied on request.
Cooling filter system TGF – K:
The cooling filter system is used for hammer mills THM-A without blower.
The heat generated during grain milling is reliably dissipated and the creation of condensate is prevented.
The filter elements are automatically cleaned by a mechanical rapping device. Compressed air is not required. The units are available with 2 or 4 m² filter surface.
TGF |
---|
700/8 |
700/12 |
900/18 |
900/27 |
K2 |
K4 |
Filter surface [m2] | max. air volume [m3/h] | autom. self cleaning |
---|---|---|
8 | 800 | no |
12 | 1200 | no |
18 | 1800 | no |
27 | 2700 | no |
2 | 200 | yes |
4 | 400 | yes |
TGF |
---|
700/8 |
700/12 |
900/18 |
900/27 |
K2 |
K4 |
Surface [m2] | Air volume [m3/h] | Self cleaning |
---|---|---|
8 | 800 | no |
12 | 1200 | no |
18 | 1800 | no |
27 | 2700 | no |
2 | 200 | yes |
4 | 400 | yes |
Larger filters on request.